FAQ ON SPARA

  • What is SPARA?

    Generally employees in a company rarely turn OFF their computers when they go on a break or leave for the day. This is mainly because the employees do not want to waste their time to turn OFF or turn ON their systems. It is made even worse by the fact that most of the employees do not know or care about the operational costs of the company.

    We have developed and are proposing a system which can eliminate nearly 90% of these losses when used together. Spara software can make sure that the power is used according to the requirement of the user and at the same time can also take care of the breaks which the employees would take.

  • How does SPARA work?

    The Spara software is a client – server software which works within an intranet and saves power through various features of the software such as Scheduling / Pattern recognition / Power Schemes etc. The Admin module has the ability to perform power down operations such as System Shutdown, Hibernate, Standby, Monitor Standby etc, on the specified client nodes by remotely configuring required settings on it.

    Software Features

    • Fully automated operation.
    • Multiple Device Control.
    • Extensive reporting.
    • User based reporting.
    • Capability to learn and adapt to existing conditions.
  • We know that SPARA uses AI algorithm and figures our pattern of behavior and we can use it schedule when computers should go to standby etc. But is that the primary way SPARA reduces power Consumption?

    The AI algorithm and local Power Schemes of Spara is triggered as soon as Spara is installed on a system. The AI algorithm takes 5 days (Customizable) to learn the pattern behavior where as the Local Power schemes starts working straight away. Once the pattern is studied both the AI algorithm and the Local Power scheme works accordingly to ensure perfect power savings.

  • Can you quantify the amt of power used by a Desktop PC using a 17” LCD monitor if switched on the whole day. Thereafter after having SPARA software run what power save do you see in a day?

    A PC with a 17” LCD would consume about 100-110 watt/hr. Given below is a table that shows per day consumption of a single PC compared to a PC installed with Spara.

    Formulae:

    ·         Working hour consumption= Working hours X % X Consumption

    ·         Lunch hour consumption= Lunch break X % X Consumption

    ·         Non Working Hour Consumption= Lock & leave X % X Consumption  + Monitor OFF & leave X % X

    ·         Consumption +  Shutdown X % X Consumption

    ·         Per day consumption= Working hour Consumption + Non working hour Consumption + Lunch hour Consumption

     

    Normal Power Consumption

    Hrs

    %

    Consumption (watts)

    Working hour consumption (watts)

    Working hours

    9

    100

    110

    990

    Non Working Hours

    14

     

     

     

    "

    Lock & leave

    40

    110

    616

    "

    Monitor off &leave

    30

    75

    315

    "

    Shutdown

    30

    10

    42

    Lunch break

    1

    100

    110

    110

     

     

     

     

     

    Per Day Consumption in KWh

     

     

     

    2.073 KWH

    Power Consumption with Spara

    Hrs

    %

    consumption (watts)

    working hour consumption(watts)

    Working hours

    9

    100

    110

    990

    Non Working Hours

    14

     

     

     

    "

    Lock & leave

    40

    30

    168

    "

    Monitor off &leave

    30

    20

    84

    "

    Shutdown

    30

    10

    42

    Lunch break

    1

    100

    30

    30

     

     

     

     

     

    Per Day Consumption in KWh

     

     

     

    1.314 KWH

  • If we provide Faronics as a Peer of SPARA – please elaborate on what SPARA and Faronics do the same and how SPARA differentiates itself from its competitor.

    (http://www.faronics.com)

    CHARACTERISTICS

    SPARA

    FARONICS

    Central Management

    Yes

    Yes

    Policy Settings

    Yes

    Yes

    OS Independent Power Management

    Yes

    No

    Scheduling

    Yes

    Yes

    Fully Autonomous

    Yes

    No

    Zero Configuration

    Yes

    No

    Wake On LAN

    Yes

    Yes

    AI Learning

     

    Yes

     

    No

     

    Application Based Control

    Yes

    Yes

    Hardware module

    Yes

    No

    Reporting

    Yes

    Yes

    Distributed Installation

    Yes

    Yes

    DB Support

    Current Version – MySql

    Next Version -Any Database

    Unknown

    OS Support

    Windows & Linux

    Windows & MAC

    Graphical User Interface

    Yes

    Yes

    User Overwrite

    Yes

    No

    RoHS Compliant

    Yes

    N/A

    State Check for Clients

    Yes

    No

    Auto Client Detect

    Yes

    No

  • Why are we different?

    This is a seriously interesting question for us as well. We google-ed, yahoo-ed, live-ed and what not-ed but we were unable to find any product in the market which is capable of comprehensively reducing the power wastage in computers as SPARA. Though there are some product which have presence in this domain, a short feature comparison will give more insight into the distinctive advantage of SPARA over the other players.

     

     

    CHARACTERISTICS

     

     

    Artin Dynamic-

    SPARA

     

    FARONICS-

    POWER SAVE

     

    IE- NIGHT WATCHMAN

     

    VERIDIEM -SURVEYOR

     

    SCRIPTLOGIC- DESKTOP AUTHORITY

    MANAGE ENGINE:

    DESKTOP POWER MANAGEMENT

     

    Central Management

    Yes

    Yes

    Yes

    Yes

    Yes

    Yes

     

    Policy Settings

    Yes

    Yes

    Yes

    Yes

    Yes

    No

     

    OS Independent Power Management

    Yes

    No

    Yes

    No

    No

    No

     

    Scheduling

     

    Yes

    Yes

    Yes

    Yes

    Yes, Strict

    Yes, Strict

     

    Fully Autonomous

     

    Yes

    No

    No

    No

    No

    No

     

    Zero Configuration

     

    Yes

    No

    No

    No

    No

    No

     

    Wake On LAN

    Yes

    Yes

    No

    Yes

    No

    No

     

    AI Learning

     

     

    Yes

     

    No

     

     

    No

     

    No

     

    No

     

    No

     

    Application Based Control

     

    Yes

    Yes

    No

    No

    No

    No

     

    Hardware Module

     

    Yes

    No

    No

    No

    No

    No

     

    Reporting

     

    Yes

    Yes

    No

    Yes

    Yes

    No

     

    Distributed Installation

     

    Yes

    Yes

    Yes

    Yes

    Yes

    Yes

    DB Support

    SQL Server, My SQL

    Unknown

    Unknown

    SQL Server

    Unknown

    Unknown

     

    OS Support

    Win XP, Vista & Linux

    Windows & MAC

    Win XP, Vista

    Win XP, Vista, Server

    Win XP, Vista, Server 2008

    Windows

     

    Graphical User Interface

     

    Yes

    Yes

    No

    Yes

    Yes

    Yes

    MSP Center Plus

     

    User Overwrite

     

    Yes

    No

    No

    No

    No

    No

     

    RoHS Compliant

     

    Yes

    N/A

    N/A

    N/A

    N/A

    N/A

    State Check for Clients

    Yes

    No

    Yes

    No

    No

    No

     

    Auto Client Detect

     

    Yes

    No

    No

    No

    No

    No

     

    Warranty/ Support

     

    2 Years

    Replacement

    1 Year Paid Service

    1 Year

    1 Year

    Unknown

    Unknown

     

    Renewal/ License

    Period

     

    Yearly

    Yearly

    25% of Cost price to be paid /year

    Unknown

    Unknown

    Unknown

     

    Cost

    TBD

    $34.56/Year

    Unknown

    Approximately $60

    Unknown

    Less than $ 1000